Parr-instrument PDM Manual de usuario Pagina 8

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 12
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 7
- 8 -
PDM Installation
Pressure Module Defaults
Keys command:
1. Press “SET” to select
2. Press return key move to next operation mode
3. Up/Down arrow keys to adjust value or select type
Main Screen: SP = 80% of span
Press return key and release
Operation
Mode
Select type/value Comment
r-S Run Run/Stop
SP to be determined** Decimal point position
AL1H 0 Upper-limit alarm 1
LoC OFF Lock mode(lock all keys or only up/down arrow
able to use)
** If units are psi, SP = 0
If units are Bar, SP = 1
If units are MPa, SP = 2
Vista de pagina 7
1 2 3 4 5 6 7 8 9 10 11 12

Comentarios a estos manuales

Sin comentarios