Parr-instrument 6755 Manual de usuario

Busca en linea o descarga Manual de usuario para Instrumentos de medición Parr-instrument 6755. Parr Instrument 6755 User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir

Indice de contenidos

Pagina 1 - Operating Instruction Manual

593M6755Solution CalorimeterOperating Instruction ManualFor models produced after November 2010

Pagina 2 - Table of Contents

3OperationParr Instrument Company8CHAPTER 3OperationMenu SystemAll confi gurations and operations are handled by a menu-driven system operated from the

Pagina 3 - PREFACE

Operation67553www.parrinst.com9Note: Changes to the program are made by use of the menu structure. Any of these items can be individually entered at

Pagina 4 - Explanation of Symbols

3OperationParr Instrument Company10Sample SizeThe rotating sample cell will hold up to 20 ml of liquid sample or a solid sample weighing up to one gra

Pagina 5

Operation67553www.parrinst.com11Emptying the CalorimeterStop the calorimeter motor, raise the cover carefully and wipe any excess liquid from the part

Pagina 6 - Installation

4Menu DescriptionsParr Instrument Company12CHAPTER 4Menu DescriptionsNote: Keys which make global changes to the setup of the calorimeter contain a Y

Pagina 7

Menu Descriptions67554www.parrinst.com13Temperature Plot Setup MenuEnable Bucket: Toggles ON/OFF.Bucket Autoscale: Toggles ON/OFF.Enable Jacket: To

Pagina 8 - Quick Start

4Menu DescriptionsParr Instrument Company14Operating Controls MenuMethod of Operation: Offers an operating mode of either combustion or solution. In

Pagina 9 - Notes

Menu Descriptions67554www.parrinst.com15Date & Time SettingsDate: Displays current date and accesses the sub-menu on which the date is set (YY/MM

Pagina 10 - Operation

4Menu DescriptionsParr Instrument Company16Data Entry Controls Menu Auto Sample ID Controls: Accesses sub-menu for controlling the automatic assignme

Pagina 11

Menu Descriptions67554www.parrinst.com17Communication Controls MenuAccesses sub-menus which set the communications protocols for the printer and balan

Pagina 12

Table of ContentsPreface Scope — 1Related Instructions — 1Customer Service — 1Explanation of Symbols — 2Safety Information — 3Intended Usage — 3Genera

Pagina 13

4Menu DescriptionsParr Instrument Company18Balance Port Settings » Number of Data Bits. Standard options for data bits. Toggles between 7 and 8. » Par

Pagina 14 - Menu Descriptions

Menu Descriptions67554www.parrinst.com19File Management MenuFile Management MenuRun Data File Manager: This key activates the File Manager. The File

Pagina 15

4Menu DescriptionsParr Instrument Company20Diagnostics MenuProvides the user with the means to test many of the components and subsystems of the Calor

Pagina 16

Menu Descriptions67554www.parrinst.com21Data Log Format: Toggles between Text Format and Data Format (csv). Data is either logged with the supportin

Pagina 17

5CalculationsParr Instrument Company22CHAPTER 5CalculationsStandardizationA sample of tris (hydroxymethyl) aminomethane, commonly called TRIS, is furn

Pagina 18

Calculations67555www.parrinst.com23Calculating the Energy ChangeThe energy change, Q, measured in this calorimeter is calculated by multiplying the ne

Pagina 19

5CalculationsParr Instrument Company24Figure 3Exothermic ReactionExample - Exothermic ReactionProblem: Determine the change in enthalpy for solid sodi

Pagina 20

Calculations67555www.parrinst.com25Figure 4Endothermic ReactionExample - Endothermic ReactionProblem: Determine the heat of solution of solid potassiu

Pagina 21

6ReportsParr Instrument Company26CHAPTER 6Reports The 6772 Calorimetric Thermom-eter can transmit its stored test data in either of two ways. The Au

Pagina 22

Memory Management67557www.parrinst.com27CHAPTER 7Memory Management The 6772 Calorimetric Thermometer will hold data for 1000 tests in its memory. Th

Pagina 23

Preface6755www.parrinst.com1PREFACE ScopeThis manual contains instructions for installing and operating the Parr 6755 Solution Calorimeter. For ease

Pagina 24 - Calculations

8Accessory ConnectionsParr Instrument Company28CHAPTER 8Accessory ConnectionsCommunication ConnectionThere is a USB connection on the rear of the 6772

Pagina 25

Accessory Connections67558www.parrinst.com29Bar Code PortThe use of barcodes in the laboratory has become a highly accurate, rapid and inexpensive way

Pagina 26

8Accessory ConnectionsParr Instrument Company30The following screenshot illustrates the contents of the Calorimetric Thermometer data directory as pre

Pagina 27

Accessory Connections67558www.parrinst.com31The Calorimetric Thermometer offers a web server service. Test reports can be viewed with a web browser us

Pagina 28 - CHAPTER 6

8Accessory ConnectionsParr Instrument Company32Clicking on the Confi g tab displays some of the confi guration options available in the 6772. Changes m

Pagina 29 - Memory Management

Accessory Connections67558www.parrinst.com33Clicking on the Run Data tab displays a list of reports currently in the instrument memory. Clicking on a

Pagina 30 - Accessory Connections

8Accessory ConnectionsParr Instrument Company34 Clicking on System Info will bring up the Software and Hardware Info screen from the 6772.

Pagina 31

Accessory Connections67558www.parrinst.com35Clicking on the LCD Snapshot Page will bring up an image of the current display on the 6772. Note that th

Pagina 32

8Accessory ConnectionsParr Instrument Company36Clicking on Documentation will provide links to the manual and other helpful documents. Note: a conne

Pagina 33

Accessory Connections67558www.parrinst.com37Remote Operation (Optional)The 6772 can be operated remotely via PC over a network with the purchase of th

Pagina 34

PrefaceParr Instrument Company2Explanation of SymbolsI On PositionO Off Position~ Alternating CurrentThis CAUTION symbol may be present on the Product

Pagina 35

9MaintenanceParr Instrument Company38CHAPTER 9MaintenanceExamine the rotating cell periodically for leaks by closing the cell and submerging the empty

Pagina 36

Troubleshooting675510www.parrinst.com39CHAPTER 10TroubleshootingError ListThe calorimeter will run a number of diagnostic checks upon itself and will

Pagina 37

11Technical ServiceParr Instrument Company40CHAPTER 11Technical ServiceContact UsTechnical Service DepartmentShould you need assistance in the operati

Pagina 38

Parts List675512www.parrinst.com41CHAPTER 12Parts ListsParts for the 6755 Solution CalorimeterPart Number DescriptionA338CEB Stirrer Drive Motor Assem

Pagina 39

13DrawingsParr Instrument Company42CHAPTER 13DrawingsExternal Parts View of 6755 Solution Calorimeter

Pagina 40 - Maintenance

Drawings675513www.parrinst.com43Internal Parts View of 6755 Solution Calorimeter

Pagina 41 - Troubleshooting

13DrawingsParr Instrument Company44USB PORTJ8J10P6P8J1A2165ETRANSITIONA1821EJ19J2A2164E BACKLIGHT CONTROL CABLE ASSYBOARD TOPIN #1SPEAKERJ5J6PIN #1LCD

Pagina 42 - Technical Service

Drawings675513www.parrinst.com45Internal Parts View of 6772 Calorimetric ThermometerASSY2X TN1140HL2X 379E2BRACKET, CAPACITOR911E FILTERINTERFERENCE,

Pagina 43 - Parts Lists

13DrawingsParr Instrument Company46Internal Parts View of 6772 Calorimetric ThermometerNote: 1262DD Capacitor Bracket and 897E Capacitor not shown for

Pagina 44 - Drawings

Drawings675513www.parrinst.com47(SEE NOTE)DATA LABEL95FBACK VIEW2X SA1332RP066-32 X 3/8 RHMS PHILLIPS6-32 X 3/8 RHMS PHILLIPSBACK PANEL (REF)327C2SA13

Pagina 45

Preface6755www.parrinst.com3Safety InformationTo avoid electrical shock, always:1. Use a properly grounded electrical outlet of correct voltage and c

Pagina 46

14Default SettingsParr Instrument Company48Calorimeter OperationStirrer OFFOperating ControlsMethod of Operation SolutionLCD Backlight Timeout(s) 120

Pagina 48

Revision 07/08/13

Pagina 49

1InstallationParr Instrument Company4CHAPTER 1InstallationThe 6755 Solution Calorimeter requires approximately 4 square feet of work space on a sturdy

Pagina 50 - Default Settings

Installation67551www.parrinst.com5Figure 1NOTE: CONNECT UNTERMINATED 493E WITH 328HC BRACKET TO THE MOTOR OUTPUT RECEPTACLE SECURING IT USING THE SA1

Pagina 51

2Quick StartParr Instrument Company6CHAPTER 2Quick Start Before starting to use the calorimeter for the fi rst time, it is recommended that the user p

Pagina 52 - Revision 07/08/13

www.parrinst.com7Notes 6755

Comentarios a estos manuales